Pepper-computer Modular Computers RS485 Manual de usuario Pagina 224

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 320
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 223
SMART I/O User’s Manual
March 12, 1996
©1996 PEP Modular Computers GmbH
Page 5 - 68
Chapter 5 Analog Modules
5.3.8.2 SMADCInit
Syntax
error_code SMADCInit(u_int8 PortNr);
Description
This function initializes the SM-THERM Module on port PortNr, and:
- identifies boards supported by this library
- provides an internal list of known sensors (contact PEP Modular
Computers for advice on sensors not included in this list)
- creates or links the data module for communication with HW task (the
module name is ‘ADC_Data’)
- starts the task accessing the Hardware (HW task)
- prepares parameters depending on the used SM-THERM module.
Input
u_int8 PortNr Port number of module to initialize
(from 0 to 10)
Output
error_code SUCCESS
E_MNF
If wrong type of module or no
module is fitted on the selected port
E_PRCABT
If starting of the HW task failed
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADCInit(0);
Vista de pagina 223
1 2 ... 219 220 221 222 223 224 225 226 227 228 229 ... 319 320

Comentarios a estos manuales

Sin comentarios