SMART I/O User’s Manual
March 12, 1996
©1996 PEP Modular Computers GmbH
Page 5 - 38
Chapter 5 Analog Modules
Figure 5.2.8.1. illustrates a typical programming structure for the correct
operation of an SM-PT100 SMART-Module.
Figure 5.2.8.1 SM-PT100 Programming Flow Diagram
SMADCSetCyclicCalib()
(for a channel)
Sleep(0)
SMADCReadConverted()
(for a channel)
Finished
SMADCDeinit()
END
START
SMADCInit()
Install Signal Handler
- OS-Intercept
SMADCSetSensorType()
(for a channel)
SMADCEnableRead()
(for a channel)
SMADCEnableConversion()
(for a channel)
SMADCSetSignal()
(for a channel)
Ye s
No